We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Harmonic diagnostic equipment.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Harmonic diagnostic equipment - List of Manufacturers, Suppliers, Companies and Products | IPROS GMS

Harmonic diagnostic equipment Product List

1~2 item / All 2 items

Displayed results

Harmonic Diagnostic Device "KS-3000 model A"

Harmonic Intelligent Degradation Diagnosis System for AC Motors & Inverters

The "KS-3000" is a harmonic diagnostic device that can identify the degree, cause, and location of abnormalities and deterioration in electrical equipment based on the magnitude of the harmonic content of the current contained in electrical devices. This diagnostic method determines the deteriorated areas and degree of deterioration using a relative method, unaffected by rated capacity, power supply impedance, load factor, installation environment, etc., and expresses the degree of abnormality and deterioration of the equipment in percentage, allowing for the assessment of abnormalities and deterioration in the equipment. 【Product Features】 ■ Supports memory expansion for 128 devices ■ Achieves weight reduction for the first time in the series ■ Realizes ultra-low pricing *For more details, please download the PDF or feel free to contact us.

  • Other inspection equipment and devices
  • Harmonic diagnostic equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Harmonic Wave Diagnostic Device Example] Cable Diagnosis

Measured with a high harmonic sensor! A case where signs of insulation abnormalities were observed in the power plant system cables.

We would like to introduce a case of cable diagnosis conducted using our harmonic diagnostic device. The measurement locations were the high-voltage substation side (IN side) and the substation side (OUT side). Each phase of the cable's IN side and OUT side was measured using a harmonic sensor. A total of six measurements were conducted in AC motor mode. The diagnosis revealed signs of insulation abnormalities in the power building system's cable. Furthermore, it was noted that if the issues can be resolved in the future, this diagnosis would be advantageous. 【Case Overview】 ■ Measurement Locations: High-voltage substation side (IN side), substation side (OUT side) ■ Measurement Method: Each phase of the cable's IN side and OUT side was measured using a harmonic sensor ■ Results - Abnormalities were observed in the power building system's cable - Attention is required regarding the power building cable (T phase) *For more details, please refer to the PDF document or feel free to contact us.

  • Contract Analysis
  • Harmonic diagnostic equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration